SVGC system = Statcom + ICMS controller + General LC

Fast response

The SVGs in the SVGC show the advantage of the electronic power switch

Fast response is implemented by SVG modules.SVG reaction time <50us, complete response time <15ms; The SVGs in the SVGC show the advantage of the electronic power switch. In the legacy SVC, the thyristor only serves as a fast switch, but cannot implement high-frequency fast switching. (The frequency is typically 100ms, while IGBT in SVGs can switch more than 15,000 times in one second.)

  • Reaction time 33.4us

  • Reaction time<50us

  • Response time14.7ms

  • Response time<15ms

Excellent compensation performance

Traditional reactive compensation may cause over- or under-compensation.
In SVGC, LCscanimplementstepwiseswitching compensation
SVG modules can cover all blind points and implementstepless switching

Realize more implement flexible LC and SVG applications

Power components in the SVGC solution (SVG modules or LCs)


can be flexibly combined to realize:SVGC compensation between -1 and +1

Adjustable pricing of the SVGC solution

SVGC solutions for different industries

  SVGC Plan A SVGC Plan B SVGC Plan C
LC 50X5 50X4 30X9
SVG 50 100 30
Compensation capacity -50~300 -100~300 -30~300

Impressive Compensation Effect

SVGC and LC can be controlled by ICMS at the same time.


Compensation effect sequence diagram when LCs and SVGs are used together (LC-compensation capacity 30kvar, SVG- 100kvar)
100~200ms:

When the load' reactive rises sharply and LCs cannot respond promptly, SVGs will instantly respond and compensate the system reactive.

200~500ms:

When LCs start compensation, SVGs will instantly lower the compensation capacity.

900~1000ms:

When load's reactive slides sharply and LCs fail to reduce capacitors used, SVGs will instantly generate a reverse compensation reactive to offset the LCs' excessive capacitors.

1000ms~:

When LCs reduce the excessive compensation capacity, SVGs will instantly track changes to the system reactive and eliminate the residual reactive in the system.

了解ICMS

ICMS:Settle the operating mode and parameter of LC and SVG. Providing 18 I/O ports to implement flexible SVG+LC applications.

SVG:Prompt response to system reactive changes, and complete reactive compensation whenLC over-compensation or under-compensation to ensure PF=0.99

General LC:Compensating the load for most stable reactive with few changes

0755-865115880755-86511588
E-mail
MessageMessage
WeChat
WeChat
在线咨询关闭
  Message         Complaint         Inquiry         Other
*
*
*
Please leave your real email or phone number so that we can respond to your staff in a timely manner!
*
Can't see clearly? Change a picture
登录注册提示
×

深圳市盛弘电气股份有限公司

盛弘电气电力电子技术的优势是模块化大功率电源产品技术,电能质量及可再生能源的各种产品均以此为平台技术,将模块化技术的效能发挥到极致。盛弘电气拥有 18项专利技术,其中9项发明专利、8项实用新型专利、1项外观设计专利。公司已经通过软件产品认证、中国电科院、信息产业部、中国质量认证中心、鉴衡、 IEEE国际电工委员会、ETL、TUV、CE、SAA等多种国内及国际认证。
找回密码
系统会自动发送《验证码》到您以上的邮箱里,请注意查看!
系统会自动发送《验证码》到您以上的邮箱里,请注意查看!
提示
×

恭喜您,评论成功!

自动关闭倒计时:2
提示
×

恭喜您,注册成功!

自动关闭倒计时:2
提示
×

恭喜您,登录成功!

自动关闭倒计时:2
提示
×

恭喜您,重设密码成功!

请重新登录
自动关闭倒计时:2